To ensure greater efficiency in the dissipation of heat generated by hydraulic systems installed on medium-heavy vehicles, Hydroven proposes the Hydrofan cooler appropriately developed to optimise management of the required work cycle.
Hydrofan is available in 3 power sizes:
- 7 kW
- 13 kW
- 20 kW
It can be supplied with painted steel or a stainless steel structure, plastic or stainless steel shell.
Documentation
Document
Document
Document
Document
The advantages of using a Hydrofan cooler rather than a traditional system with a high volume oil tank are:
- Significantly reduced oil volume.
- Compact dimensions.
- Higher availability of useful load.
Reduced maintenance and lower operating costs thanks to the volume of oil used compared to 200 - 300 L in a traditional system.
Hydrofans can be installed on vehicles used to transport:
- Fine grain products (feed, powders, etc.).
- Transport of milk and other food liquids.
- Movable surfaces.
- Gully suckers and sewage drainage.
HYDROFAN SLIM 7
Main features | |
---|---|
Oil flow rate | 110 l/min |
Circuit pressure | 250 bar |
Heat dissipation | 7 KW @ 40 °C |
Return line filtration | 25 μm |
Oil tank capacity | 13 L |
Integrated safety valve |
HYDROFAN 13
Main features | ||
---|---|---|
Oil flow rate | 40 ÷ 130 l/min | 11 ÷ 35 USgpm |
Circuit pressure | 40 ÷ 315 bar | 580 ÷ 4570 psi |
Maximum pressure allowed | 315 bar | 4568 psi |
Fan speed | 2500 rpm | 2500 rpm |
Return pressure | 1 ÷ 5 bar | 15 ÷ 75 psi |
Return line filtration | 25 µ | 0.00098 in |
Heat dissipation | 13 KW @ 40 °C | 17.4 HP @ 104 °F |
Oil tank capacity | 13 L | 3.4 US gal |
HYDROFAN 20
Main feautures | ||
---|---|---|
Oil flow rate | 55 ÷ 200 l/min | 15 ÷ 53 USgpm |
Circuit pressure | 30 ÷ 300 bar | 435 ÷ 4550 psi |
Maximum pressure allowed | 300 bar | 4550 psi |
Fan speed | 2800 rpm | 2800 rpm |
Return pressure | 1 ÷ 5 bar | 15 ÷ 75 psi |
Return line filtration | 25 µ | 0.00098 in |
Heat dissipation | 20 KW @ 40 °C | 26.8 HP @ 104 °F |
Oil tank capacity | 13 L | 3.4 US gal |